Scripting • Re: Writing to external MySql database
External monitoring tools using things like ICMP and SNMP (plus API access to log into the routers and do any extended testing) would be the best way.For real-time alerting I suggest nagios or icinga...
View ArticleGeneral • Re: Ubiquiti EdgeRouter vs MikroTik
Interesting. Thank you.I just home and office user with small network. Never touch EdgeRouter, but quite familiar with EdgeSwitch (and SwOS). Once I had an USG, but now I prefer Mikrotik.Statistics:...
View ArticleBeginner Basics • MikroTik Router L2tp
I got my Mikrotik working with the L2TP without Ipsec4011G has two switch chip bridge 0 and bridge 1 and 10g spf+L2TP give me /29 public ip address to route to.Do I need to by pass NAT for L2tp no...
View ArticleGeneral • Re: CCR2004-1G-2XS-PCIe causes INSTANT host crash when it's rebooted
I just installed two of these cards in 2 separate servers. When I reboot the Mikrotik router, one of them which has ESXi, crashes and hangs in purple screen. The one with the linux reboots. I believe...
View ArticleRouterBOARD hardware • Re: Running out of space on 16MB RouterBOARDs
There is a solution without cutting features. I own hAP ac2 and out of curiosity I looked at drivers section of ARM RouterOS. There is for example prestera_dx_max.ko file taking 687 KB of space. Then...
View ArticleGeneral • lo-Interface loopback
Hey There!Im new in this forum,I would like to share my "issue" on my home mikrotik routerOS v7.14.1 (hAP ax2).After reboot on interfaces appear a loopback interface with lo name,and when i remove it...
View ArticleGeneral • A strange day - VRRP/Wireguard
Hello! Long time no see - it's been a while since I was here now - but today has been my strangest MikroTik day in some years - so I need to ask you guys for some tips.I had a major failure at my data...
View ArticleBeginner Basics • locked out after changing subnet of router
In short, had trouble changing the subnet of a second MikroTik router in the network. The first uses the default subnet. With Safe Mode on the second router, it came back to default address after...
View ArticleGeneral • Re: Network resets a lot and looped packet message after upgraded...
So to update on this, I am inclining to believe there's something wrong with the 7.14's RSTP implementation. Once I have switch connection events, I see a lot of log items regarding looped packets and...
View ArticleRouterBOARD hardware • Re: Upgrade from RB750Gr3
At any rate DO NOT BUY A hAP ac2 !!!*shrugs* I already have one at a site, I can swap it for my RB750Gr3, just needing to transfer the configuration.Don't buy because it is previous generation now? Or...
View ArticleRouterBOARD hardware • Re: CRS310-8G+2S+ with free flying heat sink
Question 2. Fan connector in the front of fan... it is weirdThat isn't a question.. What is weird about it? Standard 4-pin fan power connection. One pin is ground, one pin is power, one pin controls...
View ArticleBeginner Basics • Re: locked out after changing subnet of router
Would be great if you can spot an error in the config or my process. Thanks in advance.If you are changing the IP don't use safe-mode. When you change the IP address it is expected that you may be...
View ArticleBeginner Basics • Re: Help SSH remote access
Hello,I have set up SSH access on my MikrotikCHR7 router and I can't access it remotely via putty or the terminal.My SSH server is on 192.168.122.59/24.My PC or I test in 192.168.1.33/24.Can you...
View ArticleBeginner Basics • Re: CCR1036 Was a proplem with version 7
Netinstall it.If the CCR1036 is an r1 version, could be failing power supply.. Many of the r1 units had poor quality caps in them.Right now my CCR1036 is showing 23.3v and it is making me nervous...
View ArticleBeginner Basics • Re: Chose cloud for Mikrotik CHR
How to change it!? help... please)Choose a previous version FreeBSD template then mount the systemrescue ISO and install according to the instructions.Statistics: Posted by kevinds — Mon Mar 18, 2024...
View ArticleRouterBOARD hardware • Re: Recent batch PSU Failures
It is useful for the community to know. Yes, do let MikroTik know directly. They probably source these power supply units and do not make them themselves.The world should know, Mikrotik is NOT...
View ArticleGeneral • Re: A strange day - VRRP/Wireguard
Quite the tale. So you have a WAN with some subnet of public IP, 10 WG tunnels, EoIP using WG peers. No BGP? e.g. just a subnet of public IPv4 on some bridge & using VRRP to potentially move...
View ArticleGeneral • Re: 24v PSU failure
Hi All. We now have 30 failed PSUs out of 300. This is a significant failure rate for mikrotik products.... It's also a pain. As it costs more to run a psu out than what it's worth. Batch numbers...
View ArticleBeginner Basics • Re: 'IPv6-only' connectivity issue
Hello again!<sigh> So I'm back at the 'no-ipv6-connectivity' message from the 'test ipv6 connectivity' sites again. I was playing with getting a /60 prefix from Xfinity (which did work, btw) and...
View ArticleRouterBOARD hardware • Re: CCR1036 Power Supply
I have lots of ccr 1036 12 g 2s first version Every unit has minimum one PSU changed. Now I change the capacitors myself even the new psu s with green capacitors blow up in relative short time....
View Article