Not to grave dig but one mistake I made as someone with very little experience with Mikrotik and bought my first device to learn and for 10gig. When I set up VLAN isolation and was blocking traffic between the VLAN's I didn't realize you could block established traffic. (I am coming from opnSense).
- User talks to IoT = Pass
- IoT responds to User = Blocked
Statistics: Posted by TrevinLC1997 — Wed Jan 08, 2025 2:12 am